Calibration (calibration)#
Start with Supervised foreground calibration workflows for supervised foreground correction and Supervised ADC post-correction: meaning, mathematics and evidence for mathematical definitions and scope.
Foreground bit-weight identification#
These functions identify affine reconstruction weights from a dedicated sine capture. The full and lite variants belong to the same calibration family.
- adctoolbox.calibrate_weight_sine(bits: ndarray | list[ndarray], freq: float | ndarray | None = None, force_search: bool | None = None, nominal_weights: ndarray | None = None, harmonic_order: int = 1, learning_rate: float = 0.5, reltol: float = 1e-12, max_iter: int = 100, verbose: int = 0, frequency_policy: str = 'python') dict[源代码]#
FGCalSine — Foreground calibration using a sinewave input
This function estimates per-bit weights and a DC offset for an ADC by fitting the weighted sum of raw bit columns to a sine series at a given (or estimated) normalized frequency Fin/Fs. Harmonic terms above the fundamental are fitted reference/nuisance terms: they can prevent source or test-chain harmonics from contaminating weight estimation, but they do not remove those harmonics from
calibrated_signal. It optionally performs a coarse and fine frequency search to refine the input tone frequency.Implementation uses a unified pipeline where single-dataset calibration is treated as a special case of multi-dataset calibration (N=1).
- 参数:
bits (ndarray or list of ndarrays) -- Binary data as matrix (N rows by M cols, N is data points, M is bitwidth). Each row is one sample; each column is a bit/segment. Can also be a list of arrays for multi-dataset calibration.
freq (float, array-like, or None, optional) -- Normalized frequency Fin/Fs. Default is None (triggers auto frequency search). Use None for automatic frequency search, a float for one frequency shared by all datasets, or an array-like value for per-dataset frequencies in multi-dataset mode.
force_search (bool or None, optional) -- Frequency fine-search policy. Default is None, which refines automatically estimated frequencies while keeping explicitly provided frequencies fixed. Set True to refine provided frequencies too, or False to disable fine search unless a zero frequency placeholder remains.
frequency_policy ({"python", "matlab"}, optional) -- Coarse frequency estimator used when
freqisNoneor zero."python"preserves the historical Python estimator."matlab"uses a MATLABwcalsin(freq=0)compatible estimator based on nominally reconstructed rank-patched bit prefixes. Explicit nonzero frequencies are not changed by this option. Default is"python".nominal_weights (array-like, optional) -- Nominal bit weights (only effective when rank is deficient). Default is 2^(M-1) down to 2^0.
harmonic_order (int, optional) -- Number of harmonic terms included in the fitted reference. Default is 1 (fundamental only). Values greater than 1 include H2/H3/... as nuisance terms in
idealand exclude them fromerror. This is useful for source/test-chain harmonic nuisance modeling; it should not be interpreted as proof that ADC harmonic distortion has been removed fromcalibrated_signal.learning_rate (float, optional) -- Adaptive learning rate for frequency updates (0..1), default is 0.5.
reltol (float, optional) -- Relative error tolerance for convergence, default is 1e-12.
max_iter (int, optional) -- Maximum iterations for fine frequency search, default is 100.
verbose (int, optional) -- Print frequency search progress (1) or not (0), default is 0.
- 返回:
Calibration result containing
weight,offset,calibrated_signal,ideal,error, andrefined_frequency.idealincludes fitted harmonics up toharmonic_order;erroris the residual after subtracting that fitted reference. The returnedsnr_dbandenobare calibration fitted-residual metrics, not FFT dynamic SNDR/ENOB whenharmonic_orderis greater than 1. Use spectrum analysis oncalibrated_signalfor ADC dynamic SNDR/THD/HDx. Therank_patchentry reports any dropped or merged rank-deficient bit columns. Array-valued entries are returned as a single array for single-dataset input or as a list of arrays for multi-dataset input.initial_frequencyrecords the coarse frequency used before fine search, andfrequency_policyrecords the coarse-estimator policy.The calibrated waveform fields use
scale_convention == "solver_unit_sine": the least-squares solve fixes the fitted fundamental sine magnitude to one. Before interpreting dBFS or NSD against a physical ADC full-scale, rescale the result withscale_calibration_outputand pass an explicit full-scale range to the spectrum analyzer.- 返回类型:
- adctoolbox.calibration.calibrate_weight_sine_lite(bits: ndarray, freq: float) ndarray[源代码]#
Minimal calibration at known frequency. Returns normalized weights. Expects well-conditioned binary data (N samples x M bits).
The returned weights are in the same solver-unit-sine convention as
calibrate_weight_sine: the fitted fundamental sine magnitude is fixed to one for identifiability. Apply an explicit scale factor before using the reconstructed waveform for physical dBFS or NSD interpretation.
Scaling and identification diagnostics#
These helpers support calibration; they are not separate identification methods.
- adctoolbox.scale_calibration_output(result: dict[str, Any], *, scale: float | None = None, target_weights: ndarray | list[float] | tuple[float, ...] | None = None, target_sine_peak: float | None = None, inplace: bool = False) dict[str, Any][源代码]#
Scale
calibrate_weight_sineoutput to a chosen ADC convention.calibrate_weight_sinefixes the fitted fundamental sine magnitude to one so that the least-squares problem is identifiable. The returnedweight,calibrated_signal,ideal, anderrorare therefore in solver-unit-sine scale by default, not automatically in an ADC voltage or code full-scale convention.This helper applies a single linear scale factor after calibration. Ratio metrics such as
snr_dbandenobare intentionally left unchanged.Exactly one scale source must be supplied:
scale: direct linear factor.target_weights: usesum(target_weights) / sum(result["weight"]).target_sine_peak: map the solver unit sine peak to this peak value.
- adctoolbox.diagnose_calibration_matrix(bits, nominal_weights=None, weights=None, *, binary_tol: float = 1e-12, constant_tol: float = 1e-12, rank_tol: float | None = None, weight_tol: float = 1e-12) dict[源代码]#
Summarize rank, conditioning, binary-ness, and weight-shape diagnostics.
This helper is intentionally diagnostic-only: it does not reject inputs and does not change calibration behavior. It is useful before or after sine-based weight calibration when checking whether the design matrix has enough observable information, whether a matrix still looks like a physical 0/1 bit-code matrix, and whether solved weights look physically plausible.
- 参数:
bits -- Calibration design matrix, or a list of matrices to stack vertically. Matrices are interpreted as
(samples, columns); wide matrices are transposed to match the calibration helpers' orientation convention.nominal_weights -- Optional nominal weights used for scale-invariant shape comparison.
weights -- Optional recovered weights to diagnose.
binary_tol -- Tolerance for considering an entry close to 0 or 1.
constant_tol -- Column range at or below this value is treated as near-constant.
rank_tol -- Optional absolute SVD/rank tolerance. If omitted, NumPy-style default tolerance
max(shape) * eps * s_maxis used.weight_tol -- Tolerance for treating weights as negative.
- 返回:
Diagnostic fields for the stacked matrix and optional weights.
- 返回类型:
Other calibration workflows#
TI sine mismatch extraction and correction are documented in Time-Interleaved ADC Analysis (timeinterleave). See Supervised foreground calibration workflows for foreground benchmarks.
Supervised foreground correction#
References must be supplied explicitly. These functions fit a direct correction
mapping, distinct from forward distortion characterization with
fit_static_nonlin. Models are JSON-compatible dictionaries.
Learned weights describe a digital correction, not individual ADC component
parameters. Normal operation evaluates a frozen model without a reference or
adaptation. See Supervised ADC post-correction: meaning, mathematics and evidence for equations and applicability.
- adctoolbox.build_calibration_features(samples, *, history=0, state=None)[源代码]#
Build current-first delayed features without fabricating startup samples.
- 参数:
samples (array_like) -- Shape (N,) or (N, C), in a fixed channel order and scale.
history (int) -- Number of preceding samples required in each feature row.
state (array_like or None) -- Previous returned
statefor a contiguous stream. Pass None at the start of every independent record; never connect unrelated waveforms.
- 返回:
featureshas columns [current channels, lag-1 channels, ...].sample_indicesselects matching labels from this input block.statecontains at most history final input rows, oldest first. A short startup block may return zero feature rows.- 返回类型:
- adctoolbox.fit_calibration_polynomial(features, reference, *, degree=3, ridge=1e-08)[源代码]#
Fit a direct inverse correction to an aligned, supplied reference.
All monomials of total degree <= degree are included. Features are scaled using training data only.
ridgepenalizes coefficients in that scaled basis: mean squared reference error + ridge * sum(non-intercept weights**2). The mapping is nonlinear in inputs for degree > 1, although fitting is linear in coefficients. More than 4096 terms is rejected to bound memory.Returns a dict with a JSON-compatible
modeland fittingdiagnostics. Apply the model to independent data usingapply_calibration(). No extrapolation accuracy, monotonicity or reference correctness is implied.design_condition_numberdiagnoses the standardized, unregularized design; it is None when numerically rank deficient, including underdetermined fits. Full rank and a finite condition number do not establish joint coverage.
- adctoolbox.fit_calibration_mlp(features, reference, *, validation_features, validation_reference, hidden_units=16, max_iterations=200, l2=1e-06, seed=1)[源代码]#
Fit a small tanh residual MLP, selecting an iterate on held-out data.
A training-only affine baseline is frozen; the fully trained one-hidden-layer network learns its residual. L-BFGS uses full-batch squared error and L2 weight regularization. Normalization and residual scale are fixed from training data. The selected model minimizes validation reference MSE over the initial state and optimizer iterates. Validation must be separate records, not test data. Returns
model,diagnosticsand per-iteratehistory. NumPy and SciPy suffice; no neural-network dependency is required. This is foreground fitting, not online adaptation.max_iterationsis an optimizer budget, not epochs. The network estimates a residual correction to the affine baseline; its weights are not physical ADC parameters. See the packaged FOREGROUND_THEORY.md for equations, reference requirements and measured-hardware literature.
- adctoolbox.apply_calibration(features, model)[源代码]#
Apply a frozen polynomial/MLP model without refitting or changing state.
Returns